Determination of Hotspot Location and Conductor Temperatures from Spare Duct Temperatures in an Underground Installation

155986-Thumbnail Image.png
Description
In this work a comparison has been made between the predictions from the models using both the present theory for the underground cable temperature prediction and the CYMCAP application and the field measurements to determine which, if any, models are

In this work a comparison has been made between the predictions from the models using both the present theory for the underground cable temperature prediction and the CYMCAP application and the field measurements to determine which, if any, models are capable of predicting the temperature and hotspot locations in an installation where the power cable is not embedded with the optical fibers and, therefore, where the cable temperatures must be inferred from the temperature measurements made in nearby spare ducts. The temperature measurements were collected from the underground 69 kV cable at the Brandow-Pickrell installation, which is a part of Salt River Project’s power sub-transmission system. The model development and the results are explained in detail. Results from the model developed have been compared and the factors affecting the cable temperature are highlighted.

Once the models were developed, it was observed that the earth surface temperature above the installation, solar radiation and other external factors such as underlying water lines, drain pipes, etc. play a key role in heating up or cooling down the power cables. It was also determined that the hotspot location in the power cable in the main duct was the same as the hotspot location in the spare duct inside the same installation.

It was also observed that the CYMCAP model had its limitations when the earth surface temperature variations were modeled in the software as the software only allows the earth’s ambient temperature to be modeled as a constant; further, results from the MATLAB model were more in line with the present theory of underground power cable temperature prediction. However, simulation results from both the MATLAB and CYMCAP model showed deviation from the measured data. It was also observed that the spare duct temperatures in this particular underground installation seemed to be affected by external factors such as solar radiation, underlying water lines, gas lines etc. which cannot be modeled in CYMCAP.
Date Created
2017
Agent

Hybrid AC-High Voltage DC Grid Stability and Controls

155927-Thumbnail Image.png
Description
The growth of energy demands in recent years has been increasing faster than the expansion of transmission facility construction. This tendency cooperating with the continuous investing on the renewable energy resources drives the research, development, and construction of HVDC projects

The growth of energy demands in recent years has been increasing faster than the expansion of transmission facility construction. This tendency cooperating with the continuous investing on the renewable energy resources drives the research, development, and construction of HVDC projects to create a more reliable, affordable, and environmentally friendly power grid.

Constructing the hybrid AC-HVDC grid is a significant move in the development of the HVDC techniques; the form of dc system is evolving from the point-to-point stand-alone dc links to the embedded HVDC system and the multi-terminal HVDC (MTDC) system. The MTDC is a solution for the renewable energy interconnections, and the MTDC grids can improve the power system reliability, flexibility in economic dispatches, and converter/cable utilizing efficiencies.

The dissertation reviews the HVDC technologies, discusses the stability issues regarding the ac and HVDC connections, proposes a novel power oscillation control strategy to improve system stability, and develops a nonlinear voltage droop control strategy for the MTDC grid.

To verify the effectiveness the proposed power oscillation control strategy, a long distance paralleled AC-HVDC transmission test system is employed. Based on the PSCAD/EMTDC platform simulation results, the proposed power oscillation control strategy can improve the system dynamic performance and attenuate the power oscillations effectively.

To validate the nonlinear voltage droop control strategy, three droop controls schemes are designed according to the proposed nonlinear voltage droop control design procedures. These control schemes are tested in a hybrid AC-MTDC system. The hybrid AC-MTDC system, which is first proposed in this dissertation, consists of two ac grids, two wind farms and a five-terminal HVDC grid connecting them. Simulation studies are performed in the PSCAD/EMTDC platform. According to the simulation results, all the three design schemes have their unique salient features.
Date Created
2017
Agent

Radiation Hardened by Design Methodologies for Soft-Error Mitigated Digital Architectures

155838-Thumbnail Image.png
Description
Digital architectures for data encryption, processing, clock synthesis, data transfer, etc. are susceptible to radiation induced soft errors due to charge collection in complementary metal oxide semiconductor (CMOS) integrated circuits (ICs). Radiation hardening by design (RHBD) techniques such as double

Digital architectures for data encryption, processing, clock synthesis, data transfer, etc. are susceptible to radiation induced soft errors due to charge collection in complementary metal oxide semiconductor (CMOS) integrated circuits (ICs). Radiation hardening by design (RHBD) techniques such as double modular redundancy (DMR) and triple modular redundancy (TMR) are used for error detection and correction respectively in such architectures. Multiple node charge collection (MNCC) causes domain crossing errors (DCE) which can render the redundancy ineffectual. This dissertation describes techniques to ensure DCE mitigation with statistical confidence for various designs. Both sequential and combinatorial logic are separated using these custom and computer aided design (CAD) methodologies.

Radiation vulnerability and design overhead are studied on VLSI sub-systems including an advanced encryption standard (AES) which is DCE mitigated using module level coarse separation on a 90-nm process with 99.999% DCE mitigation. A radiation hardened microprocessor (HERMES2) is implemented in both 90-nm and 55-nm technologies with an interleaved separation methodology with 99.99% DCE mitigation while achieving 4.9% increased cell density, 28.5 % reduced routing and 5.6% reduced power dissipation over the module fences implementation. A DMR register-file (RF) is implemented in 55 nm process and used in the HERMES2 microprocessor. The RF array custom design and the decoders APR designed are explored with a focus on design cycle time. Quality of results (QOR) is studied from power, performance, area and reliability (PPAR) perspective to ascertain the improvement over other design techniques.

A radiation hardened all-digital multiplying pulsed digital delay line (DDL) is designed for double data rate (DDR2/3) applications for data eye centering during high speed off-chip data transfer. The effect of noise, radiation particle strikes and statistical variation on the designed DDL are studied in detail. The design achieves the best in class 22.4 ps peak-to-peak jitter, 100-850 MHz range at 14 pJ/cycle energy consumption. Vulnerability of the non-hardened design is characterized and portions of the redundant DDL are separated in custom and auto-place and route (APR). Thus, a range of designs for mission critical applications are implemented using methodologies proposed in this work and their potential PPAR benefits explored in detail.
Date Created
2017
Agent

Novel Pilot Directional Protection for the FREEDM Smart Grid System

155761-Thumbnail Image.png
Description
The presence of distributed generation in high renewable energy penetration system increases the complexity for fault detection as the power flow is bidirectional. The conventional protection scheme is not sufficient for the bidirectional power flow system, hence a fast and

The presence of distributed generation in high renewable energy penetration system increases the complexity for fault detection as the power flow is bidirectional. The conventional protection scheme is not sufficient for the bidirectional power flow system, hence a fast and accurate protection scheme needs to be developed.

This thesis mainly deals with the design and validation of the protection system based on the Future Renewable Electric Energy Delivery and Management (FREEDM) system, which is a bidirectional power flow loop system. The Large-Scale System Simulation (LSSS) is a system level PSCAD model which is used to validate component models for different time-scale platforms to provide a virtual testing platform for the Future Renewable Electric Energy Delivery and Management (FREEDM) system. It is also used to validate the cases of power system protection, renewable energy integration and storage, and load profiles. The protection of the FREEDM system against any abnormal condition is one of the important tasks. Therefore, the pilot directional protection scheme based on wireless communication is used in this thesis. The use of wireless communication is extended to protect the large scale meshed distributed generation from any fault. The complete protection system consists of the main protection and the back-up protection which are both presented in the thesis. The validation of the protection system is performed on a radial system test bed using commercial relays at the ASU power laboratory, and on the RTDS platform (Real Time Digital Power System) in CAPS (Center for Advanced Power System) Florida. Considering that the commercial relays have limitations of high cost and communicating with fault isolation devices, a hardware prototype using the interface between the ADC (analog to digital converter) and MATLAB software is developed, which takes advantage of economic efficiency and communication compatibility. Part of this research work has been written into a conference paper which was presented by IEEE Green Tech Meeting, 2017.
Date Created
2017
Agent

Radiation effects measurement test structure using GF 32-nm SOI process

155707-Thumbnail Image.png
Description
This thesis describes the design of a Single Event Transient (SET) duration measurement test-structure on the Global Foundries (previously IBM) 32-nm silicon-on insulator (SOI) process. The test structure is designed for portability and allows quick design and implementation on a

This thesis describes the design of a Single Event Transient (SET) duration measurement test-structure on the Global Foundries (previously IBM) 32-nm silicon-on insulator (SOI) process. The test structure is designed for portability and allows quick design and implementation on a new process node. Such a test structure is critical in analyzing the effects of radiation on complementary metal oxide semi-conductor (CMOS) circuits. The focus of this thesis is the change in pulse width during propagation of SET pulse and build a test structure to measure the duration of a SET pulse generated in real time. This test structure can estimate the SET pulse duration with 10ps resolution. It receives the input SET propagated through a SET capture structure made using a chain of combinational gates. The impact of propagation of the SET in a >200 deep collection structure is studied. A novel methodology of deploying Thick Gate TID structure is proposed and analyzed to build multi-stage chain of combinational gates. Upon using long chain of combinational gates, the most critical issue of pulse width broadening and shortening is analyzed across critical process corners. The impact of using regular standard cells on pulse width modification is compared with NMOS and/or PMOS skewed gates for the chain of combinational gates. A possible resolution to pulse width change is demonstrated using circuit and layout design of chain of inverters, two and three inputs NOR gates. The SET capture circuit is also tested in simulation by introducing a glitch signal that mimics an individual ion strike that could lead to perturbation in SET propagation. Design techniques and skewed gates are deployed to dampen the glitch that occurs under the effect of radiation. Simulation results, layout structures of SET capture circuit and chain of combinational gates are presented.
Date Created
2017
Agent

Nuclear fission weapon yield, type, and neutron spectrum determination using thin Li-ion batteries

155506-Thumbnail Image.png
Description
With the status of nuclear proliferation around the world becoming more and more complex, nuclear forensics methods are needed to restrain the unlawful usage of nuclear devices. Lithium-ion batteries are present ubiquitously in consumer electronic devices nowadays. More importantly, the

With the status of nuclear proliferation around the world becoming more and more complex, nuclear forensics methods are needed to restrain the unlawful usage of nuclear devices. Lithium-ion batteries are present ubiquitously in consumer electronic devices nowadays. More importantly, the materials inside the batteries have the potential to be used as neutron detectors, just like the activation foils used in reactor experiments. Therefore, in a nuclear weapon detonation incident, these lithium-ion batteries can serve as sensors that are spatially distributed.

In order to validate the feasibility of such an approach, Monte Carlo N-Particle (MCNP) models are built for various lithium-ion batteries, as well as neutron transport from different fission nuclear weapons. To obtain the precise battery compositions for the MCNP models, a destructive inductively coupled plasma mass spectrometry (ICP-MS) analysis is utilized. The same battery types are irradiated in a series of reactor experiments to validate the MCNP models and the methodology. The MCNP nuclear weapon radiation transport simulations are used to mimic the nuclear detonation incident to study the correlation between the nuclear reactions inside the batteries and the neutron spectra. Subsequently, the irradiated battery activities are used in the SNL-SAND-IV code to reconstruct the neutron spectrum for both the reactor experiments and the weapon detonation simulations.

Based on this study, empirical data show that the lithium-ion batteries have the potential to serve as widely distributed neutron detectors in this simulated environment to (1) calculate the nuclear device yield, (2) differentiate between gun and implosion fission weapons, and (3) reconstruct the neutron spectrum of the device.
Date Created
2017
Agent

Online Dynamic Security Assessment Using Phasor Measurement Unit and Forecasted Load

155460-Thumbnail Image.png
Description
On-line dynamic security assessment (DSA) analysis has been developed and applied in several power dispatching control centers. Existing applications of DSA systems are limited by the assumption of the present system operating conditions and computational speeds. To overcome these obstacles,

On-line dynamic security assessment (DSA) analysis has been developed and applied in several power dispatching control centers. Existing applications of DSA systems are limited by the assumption of the present system operating conditions and computational speeds. To overcome these obstacles, this research developed a novel two-stage DSA system to provide periodic security prediction in real time. The major contribution of this research is to develop an open source on-line DSA system incorporated with Phasor Measurement Unit (PMU) data and forecast load. The pre-fault prediction of the system can provide more accurate assessment of the system and minimize the disadvantage of a low computational speed of time domain simulation.

This Thesis describes the development of the novel two-stage on-line DSA scheme using phasor measurement and load forecasting data. The computational scheme of the new system determines the steady state stability and identifies endangerments in a small time frame near real time. The new on-line DSA system will periodically examine system status and predict system endangerments in the near future every 30 minutes. System real-time operating conditions will be determined by state estimation using phasor measurement data. The assessment of transient stability is carried out by running the time-domain simulation using a forecast working point as the initial condition. The forecast operating point is calculated by DC optimal power flow based on forecast load.
Date Created
2017
Agent

Performance verification of the raptor guard installed in sub transmission systems

155140-Thumbnail Image.png
Description
In sub transmission systems, many more raptor deaths have been recorded near metal poles rather than wood poles. The metal pole, which is reliable in structure but also grounded, may increase the risk of electrocution when raptors perch on the

In sub transmission systems, many more raptor deaths have been recorded near metal poles rather than wood poles. The metal pole, which is reliable in structure but also grounded, may increase the risk of electrocution when raptors perch on the insulator. This thesis focuses on evaluating the effectiveness of the raptor guard to prevent both debilitating and lethal electrocutions to local wildlife in 69 kV sub transmission systems. First, the two-dimensional (2D) finite difference methods (FDM) were proposed to solve the Poisson and Laplace equations, which describe the electric field. Second, the verification of the FDM algorithm was made based on a parallel-plate capacitor model. Then, the potential and the electric field were simulated by the raptor-insulator model to evaluate the possibility of flashover and leakage current under various conceivable scenarios. Third, several dielectric performance experiments were implemented to gain insight into the physical property of the raptor guard developed by the Salt River Project (SRP) as an example. The proposed initial-tracking-voltage and time-to-track experiments tested the ability of the guard, which is designed to prevent the tracking phenomenon under a contaminated situation such as rain, fog, and snow. A data acquisition also collected the leakage current data for the comparison of maximum raptor tolerance. Furthermore, the puncture voltage of this guard material was performed by the dielectric breakdown voltage experiment in an oil-covered container. With the combination of the model simulation and the experiments in this research, the raptor guard was proven to be practical and beneficial in sub transmission system.
Date Created
2016
Agent

Nonlinear dynamic modeling and simulation of a passively cooled small modular reactor

155080-Thumbnail Image.png
Description
A nonlinear dynamic model for a passively cooled small modular reactor (SMR) is developed. The nuclear steam supply system (NSSS) model includes representations for reactor core, steam generator, pressurizer, hot leg riser and downcomer. The reactor core is modeled with

A nonlinear dynamic model for a passively cooled small modular reactor (SMR) is developed. The nuclear steam supply system (NSSS) model includes representations for reactor core, steam generator, pressurizer, hot leg riser and downcomer. The reactor core is modeled with the combination of: (1) neutronics, using point kinetics equations for reactor power and a single combined neutron group, and (2) thermal-hydraulics, describing the heat transfer from fuel to coolant by an overall heat transfer resistance and single-phase natural circulation. For the helical-coil once-through steam generator, a single tube depiction with time-varying boundaries and three regions, i.e., subcooled, boiling, and superheated, is adopted. The pressurizer model is developed based upon the conservation of fluid mass, volume, and energy. Hot leg riser and downcomer are treated as first-order lags. The NSSS model is incorporated with a turbine model which permits observing the power with given steam flow, pressure, and enthalpy as input. The overall nonlinear system is implemented in the Simulink dynamic environment. Simulations for typical perturbations, e.g., control rod withdrawal and increase in steam demand, are run. A detailed analysis of the results show that the steady-state values for full power are in good agreement with design data and the model is capable of predicting the dynamics of the SMR. Finally, steady-state control programs for reactor power and pressurizer pressure are also implemented and their effect on the important system variables are discussed.
Date Created
2016
Agent

SST SuperFlash modeling and simulation under ionizing radiation

154899-Thumbnail Image.png
Description
Flash memories are critical for embedded devices to operate properly but are susceptible to radiation effects, which make flash memory a key factor to improve the reliability of circuitry. This thesis describes the simulation techniques used to analyze and predict

Flash memories are critical for embedded devices to operate properly but are susceptible to radiation effects, which make flash memory a key factor to improve the reliability of circuitry. This thesis describes the simulation techniques used to analyze and predict total ionizing dose (TID) effects on 90-nm technology Silicon Storage Technology (SST) SuperFlash Generation 3 devices. Silvaco Atlas is used for both device level design and simulation purposes.

The simulations consist of no radiation and radiation modeling. The no radiation modeling details the cell structure development and characterizes basic operations (read, erase and program) of a flash memory cell. The program time is observed to be approximately 10 μs while the erase time is approximately 0.1 ms.

The radiation modeling uses the fixed oxide charge method to analyze the TID effects on the same flash memory cell. After irradiation, a threshold voltage shift of the flash memory cell is observed. The threshold voltages of a programmed cell and an erased cell are reduced at an average rate of 0.025 V/krad.

The use of simulation techniques allows designers to better understand the TID response of a SST flash memory cell and to predict cell level TID effects without performing the costly in-situ irradiation experiments. The simulation and experimental results agree qualitatively. In particular, simulation results reveal that ‘0’ to ‘1’ errors but not ‘1’ to ‘0’ retention errors occur; likewise, ‘0’ to ‘1’ errors dominate experimental testing, which also includes circuitry effects that can cause ‘1’ to ‘0’ failures. Both simulation and experimental results reveal flash memory cell TID resilience to about 200 krad.
Date Created
2016
Agent