The presence of distributed generation in high renewable energy penetration system increases the complexity for fault detection as the power flow is bidirectional. The conventional protection scheme is not sufficient for the bidirectional power flow system, hence a fast and

The presence of distributed generation in high renewable energy penetration system increases the complexity for fault detection as the power flow is bidirectional. The conventional protection scheme is not sufficient for the bidirectional power flow system, hence a fast and accurate protection scheme needs to be developed.

This thesis mainly deals with the design and validation of the protection system based on the Future Renewable Electric Energy Delivery and Management (FREEDM) system, which is a bidirectional power flow loop system. The Large-Scale System Simulation (LSSS) is a system level PSCAD model which is used to validate component models for different time-scale platforms to provide a virtual testing platform for the Future Renewable Electric Energy Delivery and Management (FREEDM) system. It is also used to validate the cases of power system protection, renewable energy integration and storage, and load profiles. The protection of the FREEDM system against any abnormal condition is one of the important tasks. Therefore, the pilot directional protection scheme based on wireless communication is used in this thesis. The use of wireless communication is extended to protect the large scale meshed distributed generation from any fault. The complete protection system consists of the main protection and the back-up protection which are both presented in the thesis. The validation of the protection system is performed on a radial system test bed using commercial relays at the ASU power laboratory, and on the RTDS platform (Real Time Digital Power System) in CAPS (Center for Advanced Power System) Florida. Considering that the commercial relays have limitations of high cost and communicating with fault isolation devices, a hardware prototype using the interface between the ADC (analog to digital converter) and MATLAB software is developed, which takes advantage of economic efficiency and communication compatibility. Part of this research work has been written into a conference paper which was presented by IEEE Green Tech Meeting, 2017.
Reuse Permissions


  • Download restricted.

    Details

    Title
    • Novel Pilot Directional Protection for the FREEDM Smart Grid System
    Contributors
    Date Created
    2017
    Resource Type
  • Text
  • Collections this item is in
    Note
    • Masters Thesis Electrical Engineering 2017

    Machine-readable links