Alginate microspheres have recently become increasingly popular in the realm of drug delivery for their biocompatibility, nontoxicity, inexpensiveness, among other factors. Recent strict regulations on microsphere size have drastically increased manufacturing cost and waste, even though the effect of…
Alginate microspheres have recently become increasingly popular in the realm of drug delivery for their biocompatibility, nontoxicity, inexpensiveness, among other factors. Recent strict regulations on microsphere size have drastically increased manufacturing cost and waste, even though the effect of size variance on drug delivery and subsequent performance is unclear. If sphere size variance does not significantly affect drug release profiles, it is possible that future ordinances may loosen tolerances in manufacturing to limit waste produced and expenditures. We use a mathematical model developed by Nickel et al. [12], to theoretically predict drug delivery profiles based on sphere size, and correlate the expected release with experimental data. This model considers diffusion as the key component for drug delivery, which is defined by Fick’s Laws of Diffusion. Alginate, chosen for its simple fabrication method and biocompatibility, was formed into microspheres with a modified extrusion technique and characterized by size. Size variance was introduced in batches and delivery patterns were compared to control groups of identical size. Release patterns for brilliant blue dye, the mock drug chosen, were examined for both groups via UV spectrometry. The absorbance values were then converted to concentration value using a calibration curve done prior to experimentation. The concentration values were then converted to mass values. These values then produced curves representing the mass of the drug released over time. Although the control and experimental values were statistically significantly different, the curves were rather similar to each other. However, when compared to the predicted release pattern, the curves were not the same. Unexpected degradation caused this dissimilarity between the curves. The predictive model was then adjusted to account for degradation by changing the diffusion coefficient in the code to a reciprocal first order exponent. The similarity between the control and experimental curves can insinuate the notion that size tolerances for microsphere production can be somewhat lenient, as a batch containing fifteen beads of the same size and one with three different sizes yields similar release patterns.
Date Created
The date the item was original created (prior to any relationship with the ASU Digital Repositories.)
Alginate microspheres have recently become increasingly popular in the realm of drug delivery for their biocompatibility, nontoxicity, inexpensiveness, among other factors. Recent strict regulations on microsphere size have drastically increased manufacturing cost and waste, even though the effect of size…
Alginate microspheres have recently become increasingly popular in the realm of drug delivery for their biocompatibility, nontoxicity, inexpensiveness, among other factors. Recent strict regulations on microsphere size have drastically increased manufacturing cost and waste, even though the effect of size variance on drug delivery and subsequent performance is unclear. If sphere size variance does not significantly affect drug release profiles, it is possible that future ordinances may loosen tolerances in manufacturing to limit waste produced and expenditures. We use a mathematical model developed by Nickel et al. [12], to theoretically predict drug delivery profiles based on sphere size, and correlate the expected release with experimental data. This model considers diffusion as the key component for drug delivery, which is defined by Fick’s Laws of Diffusion. Alginate, chosen for its simple fabrication method and biocompatibility, was formed into microspheres with a modified extrusion technique and characterized by size. Size variance was introduced in batches and delivery patterns were compared to control groups of identical size. Release patterns for brilliant blue dye, the mock drug chosen, were examined for both groups via UV spectrometry. The absorbance values were then converted to concentration value using a calibration curve done prior to experimentation. The concentration values were then converted to mass values. These values then produced curves representing the mass of the drug released over time. Although the control and experimental values were statistically significantly different, the curves were rather similar to each other. However, when compared to the predicted release pattern, the curves were not the same. Unexpected degradation caused this dissimilarity between the curves. The predictive model was then adjusted to account for degradation by changing the diffusion coefficient in the code to a reciprocal first order exponent. The similarity between the control and experimental curves can insinuate the notion that size tolerances for microsphere production can be somewhat lenient, as a batch containing fifteen beads of the same size and one with three different sizes yields similar release patterns.
Date Created
The date the item was original created (prior to any relationship with the ASU Digital Repositories.)
Polymer drug delivery system offers a key to a glaring issue in modern administration routes of drugs and biologics. Poly(lactic-co-glycolic acid) (PLGA) can be used to encapsulate drugs and biologics and deliver them into the patient, which allows high local…
Polymer drug delivery system offers a key to a glaring issue in modern administration routes of drugs and biologics. Poly(lactic-co-glycolic acid) (PLGA) can be used to encapsulate drugs and biologics and deliver them into the patient, which allows high local concentration (compared to current treatment methods), protection of the cargo from the bodily environment, and reduction in systemic side effects. This experiment used a single emulsion technique to encapsulate L-tyrosine in PLGA microparticles and UV spectrophotometry to analyze the drug release over a period of one week. The release assay found that for the tested samples, the released amount is distinct initially, but is about the same after 4 days, and they generally follow the same normalized percent released pattern. The experiment could continue with testing more samples, test the same samples for a longer duration, and look into higher w/w concentrations such as 20% or 50%.
Date Created
The date the item was original created (prior to any relationship with the ASU Digital Repositories.)
There is an increasing interest in developing thermo-responsive polymers for treating aneurysms. In this thesis project, the potential for poly(NIPAAm-co-JAAm-co-HEMA-Acrylate) (PNJHAc) as a treatment method for brain aneurysms was investigated. Five different batches of polymer were synthesized, purified, lyophilized, and…
There is an increasing interest in developing thermo-responsive polymers for treating aneurysms. In this thesis project, the potential for poly(NIPAAm-co-JAAm-co-HEMA-Acrylate) (PNJHAc) as a treatment method for brain aneurysms was investigated. Five different batches of polymer were synthesized, purified, lyophilized, and characterized using nuclear magnetic resonance and cloud point techniques over the course of several months. Two were tested in aneurysm models. Of these five batches, there were two that showed promise as liquid embolic agents for endovascular embolization.
Date Created
The date the item was original created (prior to any relationship with the ASU Digital Repositories.)
In an embolization therapy, a material is injected into a vessel to block blood flow. While this therapy is useful in starving cancerous cells it can be dangerous, with some blockades in the brain dislodging and causing strokes or blindness.…
In an embolization therapy, a material is injected into a vessel to block blood flow. While this therapy is useful in starving cancerous cells it can be dangerous, with some blockades in the brain dislodging and causing strokes or blindness. Currently, embolic materials on the market such as metal coils, balloons, and liquid embolic agents do not have a quick removal procedure. An ultrasound cleavable material could be removed in an emergency situation without invasive surgery. The primary goal of this research is to design and synthesize a polymer that can be broken down by high intensity focused ultrasound (HIFU). Initially, we have tested the ultrasound sensitive qualities on PPODA-QT hydrogel, a common embolic agent, but the gel showed no physical change after HIFU exposure. It is theorized that PNIPAAm combined with HIFU sensitive monomers can develop a temperature and ultrasound sensitive embolic agent. In our studies, poly(NIPAAm-co-tBa) had a slight lower critical solution temperature (LCST) change of about 2˚C from before to after HIFU while the study with poly(NIPAAm-co-ACL-BME) and PPODA-QT showed no change in LCST.
Date Created
The date the item was original created (prior to any relationship with the ASU Digital Repositories.)
Minimally invasive endovascular embolization procedures decrease surgery time, speed up recovery, and provide the possibility for more comprehensive treatment of aneurysms, arteriovenous malformations (AVMs), and hypervascular tumors. Liquid embolic agents (LEAs) are preferred over mechanical embolic agents, such as coils,…
Minimally invasive endovascular embolization procedures decrease surgery time, speed up recovery, and provide the possibility for more comprehensive treatment of aneurysms, arteriovenous malformations (AVMs), and hypervascular tumors. Liquid embolic agents (LEAs) are preferred over mechanical embolic agents, such as coils, because they achieve homogeneous filling of aneurysms and more complex angioarchitectures. The gold standard of commercially available LEAs is dissolved in dimethyl sulfoxide (DMSO), which has been associated with vasospasm and angiotoxicity. The aim of this study was to investigate amino acid substitution in an enzyme-degradable side group of an N-isopropylacrylamide (NIPAAm) copolymer for the development of a LEA that would be delivered in water and degrade at the rate that tissue is regenerated. NIPAAm copolymers have a lower critical solution temperature (LCST) due to their amphiphilic nature. This property enables them to be delivered as liquids through a microcatheter below their LCST and to solidify in situ above the LCST, which would result in the successful selective occlusion of blood vessels. Therefore, in this work, a series of poly(NIPAAm-co-peptide) copolymers with hydrophobic side groups containing the Ala-Pro-Gly-Leu collagenase substrate peptide sequence were synthesized as in situ forming, injectable copolymers.. The Gly-Leu peptide bond in these polypeptides is cleaved by collagenase, converting the side group into the more hydrophilic Gly-Ala-Pro-Gly-COOH (GAPG-COOH), thus increasing the LCST of the hydrogel after enzyme degradation. Enzyme degradation property and moderate mechanical stability convinces the use of these copolymers as liquid embolic agents.