Effects of Ozone Loading Rate and Ecotoxicity of Products During Ozonation of Soil Containing Weathered Crude Oil

171901-Thumbnail Image.png
Description
The world currently faces hundreds of millions of cubic meters of soil contaminated with petroleum crude oil residuals. The application of ozone gas (O3) to contaminated soil is an effective means to oxidize petrogenic compounds and, when used with bioremediation,

The world currently faces hundreds of millions of cubic meters of soil contaminated with petroleum crude oil residuals. The application of ozone gas (O3) to contaminated soil is an effective means to oxidize petrogenic compounds and, when used with bioremediation, remove the oxidized byproducts. The overarching goal of this dissertation was to evaluate two areas of potential concern to large-scale O3 deployment: the capacity of O3-treated petroleum contaminated soils to support seed germination before bioremediation and the transport characteristics of O3 in soil columns. A matched study comparing the germination outcomes of radish (Raphanus sativus L.), grass (Lagurus ovatus), and lettuce (Lactuca sativa) in soils contaminated with three crude oils at various O3 total-dose levels showed that radish germination was sensitive to the soluble byproducts of oxidized petroleum (assayed as dissolved organic carbon [DOC]), but not sensitive to the unreacted petroleum (total petroleum hydrocarbon [TPH]). A multivariable logistic regression model based on the radish results showed that adverse germination outcomes varied with the DOC concentration and that DOC ecotoxicity decreased with increasing O3 dose-level and background organic material. The model was used to create a risk management map of conditions that created 10%, 25%, and 50% extra risks of adverse radish germination. Thus, while O3 effectively lowered TPH in soils, the byproducts exhibited ecotoxicity that inhibited radish germination. On the other hand, the sensitivity of radish germination to oxidized petroleum byproducts could be utilized to assess ecological risk. The feasibility of gas transport in the soil matrix is also of paramount concern to field-scale utilization of O3. A matched study comparing TPH removal at three field-relevant loading rates (4, 12, or 36 mgozone/ gsoil/ hr) and various total dose-levels showed an anisotropic pattern along the axial distance favoring the column inlet end. The asymmetry decreased as loading rate decreased and with concurrent improvements in O3-transport distance, O3 utilization, and heat balance. Overall, a low O3 loading rate significantly improved O3 transport and utilization efficiency, while also better distributing reaction-generated heat along the gas flow path for a depth typically utilized in bioremediation field settings.
Date Created
2022
Agent