In-Band Full Duplex Analog Control and Analysis

187695-Thumbnail Image.png
Description
In-Band Full-Duplex (IBFD) can maximize the spectral resources and enable new types of technology, but generates self-interference (SI) that must be mitigated to enable practical applications. Analog domain SI cancellation (SIC), usually implemented as a digitally controlled adaptive filter, is

In-Band Full-Duplex (IBFD) can maximize the spectral resources and enable new types of technology, but generates self-interference (SI) that must be mitigated to enable practical applications. Analog domain SI cancellation (SIC), usually implemented as a digitally controlled adaptive filter, is one technique that is necessary to mitigate the interference below the noise floor. To maximize the efficiency and performance of the adaptive filter this thesis studies how key design choices impact the performance so that device designers can make better tradeoff decisions. Additionally, algorithms are introduced to maximize the SIC that incorporate the hardware constraints. The provided simulations show up to 45dB SIC with 7 bits of precision at 100MHz bandwidth.
Date Created
2023
Agent

Remote Sensing For Vital Signs Monitoring Using Advanced Radar Signal Processing Techniques

156976-Thumbnail Image.png
Description
In the past half century, low-power wireless signals from portable radar sensors, initially continuous-wave (CW) radars and more recently ultra-wideband (UWB) radar systems, have been successfully used to detect physiological movements of stationary human beings.

The thesis starts with

In the past half century, low-power wireless signals from portable radar sensors, initially continuous-wave (CW) radars and more recently ultra-wideband (UWB) radar systems, have been successfully used to detect physiological movements of stationary human beings.

The thesis starts with a careful review of existing signal processing techniques and state of the art methods possible for vital signs monitoring using UWB impulse systems. Then an in-depth analysis of various approaches is presented.

Robust heart-rate monitoring methods are proposed based on a novel result: spectrally the fundamental heartbeat frequency is respiration-interference-limited while its higher-order harmonics are noise-limited. The higher-order statistics related to heartbeat can be a robust indication when the fundamental heartbeat is masked by the strong lower-order harmonics of respiration or when phase calibration is not accurate if phase-based method is used. Analytical spectral analysis is performed to validate that the higher-order harmonics of heartbeat is almost respiration-interference free. Extensive experiments have been conducted to justify an adaptive heart-rate monitoring algorithm. The scenarios of interest are, 1) single subject, 2) multiple subjects at different ranges, 3) multiple subjects at same range, and 4) through wall monitoring.

A remote sensing radar system implemented using the proposed adaptive heart-rate estimation algorithm is compared to the competing remote sensing technology, a remote imaging photoplethysmography system, showing promising results.

State of the art methods for vital signs monitoring are fundamentally related to process the phase variation due to vital signs motions. Their performance are determined by a phase calibration procedure. Existing methods fail to consider the time-varying nature of phase noise. There is no prior knowledge about which of the corrupted complex signals, in-phase component (I) and quadrature component (Q), need to be corrected. A precise phase calibration routine is proposed based on the respiration pattern. The I/Q samples from every breath are more likely to experience similar motion noise and therefore they should be corrected independently. High slow-time sampling rate is used to ensure phase calibration accuracy. Occasionally, a 180-degree phase shift error occurs after the initial calibration step and should be corrected as well. All phase trajectories in the I/Q plot are only allowed in certain angular spaces. This precise phase calibration routine is validated through computer simulations incorporating a time-varying phase noise model, controlled mechanic system, and human subject experiment.
Date Created
2018
Agent