Accuracy of Neck Circumference in Classifying Overweight and Obese US Children

128331-Thumbnail Image.png
Description

Objective: To evaluate classification accuracy of NC and compare it with body mass index (BMI) in identifying overweight/obese US children.

Methods: Data were collected from 92 children (boys: 61) aged 7 to 13 over a 2-year period. NC, BMI, and percent

Objective: To evaluate classification accuracy of NC and compare it with body mass index (BMI) in identifying overweight/obese US children.

Methods: Data were collected from 92 children (boys: 61) aged 7 to 13 over a 2-year period. NC, BMI, and percent of body fat (BF%) were measured in each child and their corresponding cut-off values were applied to classify the children as being overweight/obese. Classification accuracy of NC and BMI was systematically investigated for boys and girls in relation to true overweight/obesity categorization as assessed with a criterion measure of BF% (i.e., Bod Pod).

Results: For boys, Cohen’s k (0.25), sensitivity (38.1%), and specificity (85.0%) of NC were smaller in comparison with Cohen’s k (0.57), sensitivity (57.1%), and specificity (95.0%) of BMI in relation to BF% categorization. For girls, Cohen’s k (0.45), sensitivity (50.0%), and specificity (91.3%) of NC were smaller in comparison with Cohen’s k (0.52), sensitivity (50.0%), and specificity (95.7%) of BMI.

Conclusion: NC measurement was not better than BMI in classifying childhood overweight/obesity and, for boys, NC was inferior to BMI. Pediatricians and/or pediatric researchers should be cautious or wary about incorporating NC measurements in their pediatric care and/or research.

Date Created
2014-01-30
Agent

Examination of Different Accelerometer Cut-Points for Assessing Sedentary Behaviors in Children

128881-Thumbnail Image.png
Description

Background: Public health research on sedentary behavior (SB) in youth has heavily relied on accelerometers. However, it has been limited by the lack of consensus on the most accurate accelerometer cut-points as well as by unknown effects caused by accelerometer position

Background: Public health research on sedentary behavior (SB) in youth has heavily relied on accelerometers. However, it has been limited by the lack of consensus on the most accurate accelerometer cut-points as well as by unknown effects caused by accelerometer position (wrist vs. hip) and output (single axis vs. multiple axes). The present study systematically evaluates classification accuracy of different Actigraph cut-points for classifying SB using hip and wrist-worn monitors and establishes new cut-points to enable use of the 3-dimensional vector magnitude data (for both hip and wrist placement).

Methods: A total of 125 children ages 7–13 yrs performed 12 randomly selected activities (from a set of 24 different activities) for 5 min each while wearing tri-axial Actigraph accelerometers on both the hip and wrist. The accelerometer data were categorized as either sedentary or non-sedentary minutes using six previously studied cut-points: 100counts-per-minute (CPM), 200CPM, 300CPM, 500CPM, 800CPM and 1100CPM. Classification accuracy was evaluated with Cohen's Kappa (κ) and new cut-points were identified from Receiver Operating Characteristic (ROC).

Results: Of the six cut-points, the 100CPM value yielded the highest classification accuracy (κ = 0.81) for hip placement. For wrist placement, all of the cut-points produced low classification accuracy (ranges of κ from 0.44 to 0.67). Optimal sedentary cut-points derived from ROC were 554.3CPM (ROC-AUC of 0.99) for vector magnitude for hip, 1756CPM (ROC-AUC of 0.94) for vertical axis for wrist, and 3958.3CPM (ROC-AUC of 0.93) for vector magnitude for wrist placement.

Conclusions: The 100CPM was supported for use with vertical axis for hip placement, but not for wrist placement. The ROC-derived cut-points can be used to classify youth SB with the wrist and with vector magnitude data.

Date Created
2014-04-03
Agent