Single particle diffractive imaging data from Rice Dwarf Virus (RDV) were recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS). RDV was chosen as it is a well-characterized model system, useful for proof-of-principle experiments, system optimization and algorithm development. RDV, an icosahedral virus of about 70 nm in diameter, was aerosolized and injected into the approximately 0.1 μm diameter focused hard X-ray beam at the CXI instrument of LCLS. Diffraction patterns from RDV with signal to 5.9 Ångström were recorded. The diffraction data are available through the Coherent X-ray Imaging Data Bank (CXIDB) as a resource for algorithm development, the contents of which are described here.
Details
- Coherent Diffraction of Single Rice Dwarf Virus Particles Using Hard X-rays at the Linac Coherent Light Source
- Munke, Anna (Author)
- Andreasson, Jakob (Author)
- Aquila, Andrew (Author)
- Awel, Salah (Author)
- Ayyer, Kartik (Author)
- Barty, Anton (Author)
- Bean, Richard J. (Author)
- Berntsen, Peter (Author)
- Bielecki, Johan (Author)
- Boutet, Sebastien (Author)
- Bucher, Maximilian (Author)
- Chapman, Henry N. (Author)
- Daurer, Benedikt J. (Author)
- DeMirci, Hasan (Author)
- Elser, Veit (Author)
- Fromme, Petra (Author)
- Hajdu, Janos (Author)
- Hantke, Max F. (Author)
- Higashiura, Akifumi (Author)
- Hogue, Brenda (Author)
- Hosseinizadeh, Ahmad (Author)
- Kim, Yoonhee (Author)
- Kirian, Richard (Author)
- Reddy, Hemanth K. N. (Author)
- Lan, Ti-Yen (Author)
- Larsson, Daniel S. D. (Author)
- Liu, Haiguang (Author)
- Loh, N. Duane (Author)
- Maia, Filipe R. N. C. (Author)
- Mancuso, Adrian P. (Author)
- Muhlig, Kerstin (Author)
- Nakagawa, Atsushi (Author)
- Nam, Daewoong (Author)
- Nelson, Garrett (Author)
- Nettelblad, Carl (Author)
- Okamoto, Kenta (Author)
- Ourmazd, Abbas (Author)
- Rose, Max (Author)
- van der Schot, Gijs (Author)
- Schwander, Peter (Author)
- Seibert, M. Marvin (Author)
- Sellberg, Jonas A. (Author)
- Sierra, Raymond G. (Author)
- Song, Changyong (Author)
- Svenda, Martin (Author)
- Timneanu, Nicusor (Author)
- Vartanyants, Ivan A. (Author)
- Westphal, Daniel (Author)
- Wiedom, Max O. (Author)
- Williams, Garth J. (Author)
- Xavier, Paulraj Lourdu (Author)
- Soon, Chun Hong (Author)
- Zook, James (Author)
- College of Liberal Arts and Sciences (Contributor, Contributor)
- School of Molecular Sciences (Contributor)
- Biodesign Institute (Contributor)
- Applied Structural Discovery (Contributor)
- School of Life Sciences (Contributor)
- Infectious Diseases and Vaccinology (Contributor)
- Department of Physics (Contributor)
- Digital object identifier: 10.1038/sdata.2016.64
- Identifier TypeInternational standard serial numberIdentifier Value2052-4463
- The final version of this article, as published in Scientific Data, can be viewed online at: https://www.nature.com/articles/sdata201664
Citation and reuse
Cite this item
This is a suggested citation. Consult the appropriate style guide for specific citation guidelines.
Munke, A., Andreasson, J., Aquila, A., Awel, S., Ayyer, K., Barty, A., . . . Zook, J. (2016). Coherent diffraction of single Rice Dwarf virus particles using hard X-rays at the Linac Coherent Light Source. Scientific Data, 3, 160064. doi:10.1038/sdata.2016.64