Description
Purpose: To evaluate a new method of measuring ocular exposure in the context of a natural blink pattern through analysis of the variables tear film breakup time (TFBUT), interblink interval (IBI), and tear film breakup area (BUA).
Methods: The traditional methodology

Purpose: To evaluate a new method of measuring ocular exposure in the context of a natural blink pattern through analysis of the variables tear film breakup time (TFBUT), interblink interval (IBI), and tear film breakup area (BUA).
Methods: The traditional methodology (Forced-Stare [FS]) measures TFBUT and IBI separately. TFBUT is measured under forced-stare conditions by an examiner using a stopwatch, while IBI is measured as the subject watches television. The new methodology (video capture manual analysis [VCMA]) involves retrospective analysis of video data of fluorescein-stained eyes taken through a slit lamp while the subject watches television, and provides TFBUT and BUA for each IBI during the 1-minute video under natural blink conditions. The FS and VCMA methods were directly compared in the same set of dry-eye subjects. The VCMA method was evaluated for the ability to discriminate between dry-eye subjects and normal subjects. The VCMA method was further evaluated in the dry eye subjects for the ability to detect a treatment effect before, and 10 minutes after, bilateral instillation of an artificial tear solution.
Results: Ten normal subjects and 17 dry-eye subjects were studied. In the dry-eye subjects, the two methods differed with respect to mean TFBUTs (5.82 seconds, FS; 3.98 seconds, VCMA; P = 0.002). The FS variables alone (TFBUT, IBI) were not able to successfully distinguish between the dry-eye and normal subjects, whereas the additional VCMA variables, both derived and observed (BUA, BUA/IBI, breakup rate), were able to successfully distinguish between the dry-eye and normal subjects in a statistically significant fashion. TFBUT (P = 0.034) and BUA/IBI (P = 0.001) were able to distinguish the treatment effect of artificial tears in dry-eye subjects.
Conclusion: The VCMA methodology provides a clinically relevant analysis of tear film stability measured in the context of a natural blink pattern.
Reuse Permissions
  • Downloads
    PDF (542.9 KB)

    Details

    Title
    • Measurement of ocular surface protection under natural blink conditions
    Date Created
    2011-09-21
    Resource Type
  • Text
  • Collections this item is in
    Identifier
    • Digital object identifier: 10.2147/OPTH.S22017
    • Identifier Type
      International standard serial number
      Identifier Value
      1177-5467
    • Identifier Type
      International standard serial number
      Identifier Value
      1177-5483
    Note
    • The final version of this article, as published in Clinical Ophthalmology, can be viewed online at: https://www.dovepress.com/measurement-of-ocular-surface-protection-under-natural-blink-condition-peer-reviewed-article-OPTH

    Citation and reuse

    Cite this item

    This is a suggested citation. Consult the appropriate style guide for specific citation guidelines.

    Mclaughlin, J., Abelson, R., Lane, K., Johnston, P., O., & Montgomery, D. (2011). Measurement of ocular surface protection under natural blink conditions. Clinical Ophthalmology, 1349. doi:10.2147/opth.s22017

    Machine-readable links