Description

The modified Thomas test was developed to assess the presence of hip flexion contracture and to measure hip extensibility. Despite its widespread use, to the authors’ knowledge, its criterion reference validity has not yet been investigated. The purpose of this

The modified Thomas test was developed to assess the presence of hip flexion contracture and to measure hip extensibility. Despite its widespread use, to the authors’ knowledge, its criterion reference validity has not yet been investigated. The purpose of this study was to assess the criterion reference validity of the modified Thomas test for measuring peak hip extension angle and hip extension deficits, as defined by the hip not being able to extend to 0º, or neutral. Twenty-nine healthy college students (age = 22.00 ± 3.80 years; height = 1.71 ± 0.09 m; body mass = 70.00 ± 15.60 kg) were recruited for this study. Bland–Altman plots revealed poor validity for the modified Thomas test’s ability to measure hip extension, which could not be explained by differences in hip flexion ability alone. The modified Thomas test displayed a sensitivity of 31.82% (95% CI [13.86–54.87]) and a specificity of 57.14% (95% CI [18.41–90.10]) for testing hip extension deficits. It appears, however, that by controlling pelvic tilt, much of this variance can be accounted for (r = 0.98). When pelvic tilt is not controlled, the modified Thomas test displays poor criterion reference validity and, as per previous studies, poor reliability. However, when pelvic tilt is controlled, the modified Thomas test appears to be a valid test for evaluating peak hip extension angle.

Reuse Permissions
  • Downloads
    PDF (273.4 KB)
    Download count: 4

    Details

    Title
    • The Modified Thomas Test is Not a Valid Measure of Hip Extension Unless Pelvic Tilt is Controlled
    Contributors
    Date Created
    2016-08-11
    Resource Type
  • Text
  • Collections this item is in
    Identifier
    • Digital object identifier: 10.7717/peerj.2325
    • Identifier Type
      International standard serial number
      Identifier Value
      2167-8359
    Note
    • The final version of this article, as published in PeerJ, can be viewed online at: https://peerj.com/articles/2325/

    Citation and reuse

    Cite this item

    This is a suggested citation. Consult the appropriate style guide for specific citation guidelines.

    Vigotsky, A. D., Lehman, G. J., Beardsley, C., Contreras, B., Chung, B., & Feser, E. H. (2016). The modified Thomas test is not a valid measure of hip extension unless pelvic tilt is controlled. PeerJ, 4. doi:10.7717/peerj.2325

    Machine-readable links