The performance of the Alpha Sprayed Polyurethane Foam (SPF) roofing system is perceived as not an economical option when compared to a 20-year modified bitumen roofing system. Today, the majority of roofs are being replaced, rather than newly installed. The coating manufacturer, Neogard, implemented the Alpha roofing program to identify the best contractors in the industry and to measure their roof performance. The Alpha roof system has shown consistent high performance on over 230 million square feet of surveyed roof. The author proposes to identify if the Alpha roof system is renewable, has proven performance that competes with the traditional modified roofing system, and is a more economical option by evaluating an Alpha roof system installation and the performance of a 29-year-old Alpha roof system. The Dallas Independent School District utilized the Alpha program for William Lipscomb Elementary School in 2016. Dallas Fort Worth Urethane installed the Alpha SPF roof system with high customer satisfaction ratings. This roofing installation showed the value of the Alpha roof system by saving over 20% on costs for the installation and will save approximately 69% of costs on the recoating of the roof in 20 years. The Casa View Elementary School roof system was installed with a Neogard Permathane roof system in 1987. This roof was hail tested with ten drops from 17 feet 9 inches of 1-3/4-inch steel ball (9 out of 10 passed) and four drops from 17 feet 9 inches with a 3-inch diameter steel ball (2 out of 4 passed). The analysis of the passing and failing core samples show that the thickness of the top and base Alpha SPF coating is one of the major differences in a roof passing or failing the FM-SH hail test. Over the 40-year service life, the main difference of purchasing a 61,000 square feet Alpha SPF roof versus modified bitumen roof are savings of approximately $1,067,500. Past hail tests on Alpha SPF roof systems show its cost effectiveness with high customer satisfaction (9.8 out of 10), an over 40-year service life after a $6.00/SF recoat and savings of over $1M for DISD.
Details
Title
- Cost-effectiveness in roofing: Alpha SPF roofs
Contributors
- Zulanas, Charles J., IV (Author)
- Kashiwagi, Dean T. (Thesis advisor)
- Kashiwagi, Jacob S (Thesis advisor)
- Chong, Oswald (Committee member)
- Arizona State University (Publisher)
Date Created
The date the item was original created (prior to any relationship with the ASU Digital Repositories.)
2017
Subjects
- engineering
- Sustainability
- Civil Engineering
- Alpha SPF
- Facility management
- FM-SH testing
- Neogard
- roof hail tests
- sprayed polyurethane foam roofing
- Polyurethanes
- Plastic foams
- Roofing--Economic aspects.
- Roofing
- Roofing--Environmental aspects.
- Roofing
- Roofs--Maintenance and repair--Economic aspects.
- Roofs
- Roofs--Maintenance and repair--Environmental aspects.
- Roofs
Resource Type
Collections this item is in
Note
- thesisPartial requirement for: M.S., Arizona State University, 2017
- bibliographyIncludes bibliographical references (pages 54-55)
- Field of study: Construction
Citation and reuse
Statement of Responsibility
by Charles J. Zulanas IV