Full metadata
Title
Angle of incidence and power degradation analysis of photovoltaic modules
Description
Photovoltaic (PV) module nameplates typically provide the module's electrical characteristics at standard test conditions (STC). The STC conditions are: irradiance of 1000 W/m2, cell temperature of 25oC and sunlight spectrum at air mass 1.5. However, modules in the field experience a wide range of environmental conditions which affect their electrical characteristics and render the nameplate data insufficient in determining a module's overall, actual field performance. To make sound technical and financial decisions, designers and investors need additional performance data to determine the energy produced by modules operating under various field conditions. The angle of incidence (AOI) of sunlight on PV modules is one of the major parameters which dictate the amount of light reaching the solar cells. The experiment was carried out at the Arizona State University- Photovoltaic Reliability Laboratory (ASU-PRL). The data obtained was processed in accordance with the IEC 61853-2 model to obtain relative optical response of the modules (response which does not include the cosine effect). The results were then compared with theoretical models for air-glass interface and also with the empirical model developed by Sandia National Laboratories. The results showed that all modules with glass as the superstrate had identical optical response and were in agreement with both the IEC 61853-2 model and other theoretical and empirical models. The performance degradation of module over years of exposure in the field is dependent upon factors such as environmental conditions, system configuration, etc. Analyzing the degradation of power and other related performance parameters over time will provide vital information regarding possible degradation rates and mechanisms of the modules. An extensive study was conducted by previous ASU-PRL students on approximately 1700 modules which have over 13 years of hot- dry climatic field condition. An analysis of the results obtained in previous ASU-PRL studies show that the major degradation in crystalline silicon modules having glass/polymer construction is encapsulant discoloration (causing short circuit current drop) and solder bond degradation (causing fill factor drop due to series resistance increase). The power degradation for crystalline silicon modules having glass/glass construction was primarily attributed to encapsulant delamination (causing open-circuit voltage drop).
Date Created
2013
Contributors
- Vasantha Janakeeraman, Suryanarayana (Author)
- Tamizhmani, Govindasamy (Thesis advisor)
- Rogers, Bradley (Committee member)
- Macia, Narciso (Committee member)
- Arizona State University (Publisher)
Topical Subject
Resource Type
Extent
xi, 84 p. : col. ill
Language
eng
Copyright Statement
In Copyright
Primary Member of
Peer-reviewed
No
Open Access
No
Handle
https://hdl.handle.net/2286/R.I.17954
Statement of Responsibility
by Suryanarayana Vasantha Janakeeraman
Description Source
Viewed on Dec. 11, 2013
Level of coding
full
Note
thesis
Partial requirement for: M.S.Tech, Arizona State University, 2013
bibliography
Includes bibliographical references (p. 33)
Field of study: Electrical engineering
System Created
- 2013-07-12 06:24:59
System Modified
- 2021-08-30 01:41:22
- 3 years 2 months ago
Additional Formats