ABSTRACT Leadership in Energy and Environmental Design (LEED) is a non-governmental organization of U.S. Green Building Council (USGBC) which promotes a sustainable built environment with its rating systems. One of the building segments which it considers is healthcare, where it

ABSTRACT Leadership in Energy and Environmental Design (LEED) is a non-governmental organization of U.S. Green Building Council (USGBC) which promotes a sustainable built environment with its rating systems. One of the building segments which it considers is healthcare, where it is a challenge to identify the most cost-effective variety of complex equipments, to meet the demand for 24/7 health care and diagnosis, and implement various energy efficient strategies in inpatient hospitals. According to their “End Use Monitoring” study, Hospital Energy Alliances (HEA), an initiative of U.S. Department of Energy (DOE), reducing plug load reduces hospital energy consumption. The aim of this thesis is to investigate the extent to which realistic changes to the building envelope, together with HVAC and operation schedules would allow LEED credits to be earned in the DOE–hospital prototype. The scope of this research is to specifically investigate the inpatient block where patient stays longer. However, to obtain LEED credits the percentage cost saving should be considered along with the end use monitoring. Several steps have been taken to identify the optimal set of the end use results by adopting the Whole Building Energy Simulation option of the LEED Energy & Atmosphere (EA) pre– requisite 2: Minimum Energy Performance. The initial step includes evaluating certain LEED criteria consistent with ASHRAE Standard 90.1–2007 with the constraint that hospital prototype is to be upgraded from Standard 2004 to Standard 2007. The simulation method stipulates energy conservation measures as well as utility costing to enhance the LEED credits. A series of simulations with different values of Light Power Density, Sizing Factors, Chiller Coefficient of Performance, Boiler Efficiency, Plug Loads and utility cost were run for a variety of end uses with the extreme climatic condition of Phoenix. These assessments are then compared and used as a framework for a proposed interactive design decision approach. As a result, a total of 19.4% energy savings and 20% utility cost savings were achieved by the building simulation tool, which refer to 5 and 7 LEED credits respectively. The study develops a proper framework for future evaluations intended to achieve more LEED points.
Reuse Permissions


  • Download restricted.

    Details

    Title
    • Obtaining LEED credits directed towards healthy inpatient block
    Contributors
    Date Created
    2012
    Resource Type
  • Text
  • Collections this item is in
    Note
    • thesis
      Partial requirement for: M.S., Arizona State University, 2012
    • bibliography
      Includes bibliographical references (p. 69-70)
    • Field of study: Built environment (Energy performance & climate responsive architecture)

    Citation and reuse

    Statement of Responsibility

    by Sadia Khandaker Haque