Description
Treatment of cerebral aneurysms using non-invasive methods has existed for decades. Since the advent of modern endovascular techniques, advancements to embolic materials have largely focused on improving platinum coil technology. However, the recent development of Onyx®, a liquid-delivery precipitating polymer system, has opened the door for a new class of embolic materials--liquid-fill systems. These liquid-fill materials have the potential to provide better treatment outcomes than platinum coils. Initial clinical use of Onyx has proven promising, but not without substantial drawbacks, such as co-delivery of angiotoxic compounds and an extremely technical delivery procedure. This work focuses on formulation, characterization and testing of a novel liquid-to-solid gelling polymer system, based on poly(propylene glycol) diacrylate (PPODA) and pentaerythritol tetrakis(3-mercaptopropionate) (QT). The PPODA-QT system bypasses difficulties associated with Onyx embolization, yet still maintains non-invasive liquid delivery--exhibiting the properties of an ideal embolic material for cerebral aneurysm embolization. To allow for material visibility during clinical delivery, an embolic material must be radio-opaque. The PPODA-QT system was formulated with commercially available contrast agents and the gelling kinetics were studied, as a complete understanding of the gelling process is vital for clinical use. These PPODA-QT formulations underwent in vitro characterization of material properties including cytotoxicity, swelling, and degradation behaviors. Formulation and characterization tests led to an optimized PPODA-QT formulation that was used in subsequent in vivo testing. PPODA-QT formulated with the liquid contrast agent ConrayTM was used in the first in vivo studies. These studies employed a swine aneurysm model to assess initial biocompatibility and test different delivery strategies of PPODA-QT. Results showed good biocompatibility and a suitable delivery strategy, providing justification for further in vivo testing. PPODA-QT was then used in a small scale pilot study to gauge long-term effectiveness of the material in a clinically-relevant aneurysm model. Results from the pilot study showed that PPODA-QT has the capability to provide successful, long-term treatment of model aneurysms as well as facilitate aneurysm healing.
Download count: 1
Details
Title
- A liquid-to-solid gelling polymer system for cerebral aneurysm embolization: : formulation, characterization, and testing
Contributors
- Riley, Celeste (Author)
- Vernon, Brent L (Thesis advisor)
- Preul, Mark C (Committee member)
- Frakes, David (Committee member)
- Pauken, Christine (Committee member)
- Massia, Stephen (Committee member)
- Arizona State University (Publisher)
Date Created
The date the item was original created (prior to any relationship with the ASU Digital Repositories.)
2011
Subjects
Resource Type
Collections this item is in
Note
-
thesisPartial requirement for: Ph.D., Arizona State University, 2011
-
bibliographyIncludes bibliographical references (p. 148-158)
-
Field of study: Biomedical engineering
Citation and reuse
Statement of Responsibility
by Celeste Riley