Finite element analysis on the effects of elastomeric inclusions for abating heat transfer in steel reinforced concrete columns
Description
Concrete columns constitute the fundamental supports of buildings, bridges, and various other infrastructures, and their failure could lead to the collapse of the entire structure. As such, great effort goes into improving the fire resistance of such columns. In a time sensitive fire situation, a delay in the failure of critical load bearing structures can lead to an increase in time allowed for the evacuation of occupants, recovery of property, and access to the fire. Much work has been done in improving the structural performance of concrete including reducing column sizes and providing a safer structure. As a result, high-strength (HS) concrete has been developed to fulfill the needs of such improvements. HS concrete varies from normal-strength (NS) concrete in that it has a higher stiffness, lower permeability and larger durability. This, unfortunately, has resulted in poor performance under fire. The lower permeability allows for water vapor to build up causing HS concrete to suffer from explosive spalling under rapid heating. In addition, the coefficient of thermal expansion (CTE) of HS concrete is lower than that of NS concrete. In this study, the effects of introducing a region of crumb rubber concrete into a steel-reinforced concrete column were analyzed. The inclusion of crumb rubber concrete into a column will greatly increase the thermal resistivity of the overall column, leading to a reduction in core temperature as well as the rate at which the column is heated. Different cases were analyzed while varying the positioning of the crumb-rubber region to characterize the effect of position on the improvement of fire resistance. Computer simulated finite element analysis was used to calculate the temperature and strain distribution with time across the column's cross-sectional area with specific interest in the steel - concrete region. Of the several cases which were investigated, it was found that the improvement of time before failure ranged between 32 to 45 minutes.
Date Created
2011
Contributors
- Ziadeh, Bassam Mohammed (Author)
- Phelan, Patrick (Thesis advisor)
- Kaloush, Kamil (Thesis advisor)
- Jiang, Hanqing (Committee member)
- Arizona State University (Publisher)
Topical Subject
Resource Type
Extent
xi, 71 p. : ill. (some col.)
Language
eng
Copyright Statement
In Copyright
Primary Member of
Peer-reviewed
No
Open Access
No
Handle
https://hdl.handle.net/2286/R.I.9331
Statement of Responsibility
by Bassam Mohammed Ziadeh
Description Source
Viewed on Oct. 23, 2012
Level of coding
full
Note
thesis
Partial requirement for: M.S., Arizona State University, 2011
bibliography
Includes bibliographical references (p. 67-71)
Field of study: Mechanical engineering
System Created
- 2011-08-12 04:55:16
System Modified
- 2021-08-30 01:51:56
- 3 years 2 months ago
Additional Formats