Full metadata
Title
Reducing The Scale of Steam Generators in Pressurized Water Reactors
Description
Nuclear power has recently experienced a resurgence in interest due to its ability to generate significant amounts of relatively clean energy. However, the overall size of nuclear power plants still poses a problem to future advancements. The bulkiness of components in the plant contribute to longer construction times, higher building and maintenance costs, and the isolation of nuclear plants from populated areas. The goal of this project was to analyze the thermal performance of nanocrystalline copper tantalum (NC Cu-Ta) inside the steam generator of a pressurized water reactor to see how much the size of these units could be reduced without affecting the amount of heat transferred through it. The analysis revealed that using this material, with its higher thermal conductivity than the traditional Inconel Alloy 600 that is typically used in steam generators, it is possible to reduce the height of a steam generator from 21 meters to about 18.6 meters, signifying a 11.6% reduction in height. This analysis also revealed a diminishing return that occurs with increasing the thermal conductivity on both reducing the required heat transfer area and increasing the overall heat transfer coefficient.
Date Created
2019-05
Contributors
- Riese, Alexander (Author)
- Phelan, Patrick (Thesis director)
- Bocanegra, Luis (Committee member)
- Mechanical and Aerospace Engineering Program (Contributor)
- Barrett, The Honors College (Contributor)
Topical Subject
Resource Type
Extent
36 pages
Language
eng
Copyright Statement
In Copyright
Primary Member of
Series
Academic Year 2018-2019
Handle
https://hdl.handle.net/2286/R.I.52614
Level of coding
minimal
Cataloging Standards
System Created
- 2019-04-18 12:00:20
System Modified
- 2021-08-11 04:09:57
- 3 years 3 months ago
Additional Formats