Full metadata
Title
Impact of Misting Systems on Local Air Quality
Description
-Please adjust the format of the abstract. m-3 should be typed as "m to the minus 3" with the "minus 3" in superscript
-see the additional "abstract.pdf" document for formatting
In arid environments like Phoenix, many professional and residential outdoor spaces are cooled by the use of misting systems. These systems spray a fine mist of water droplets that cool down the surrounding air through the endothermic evaporation process. When the water droplets evaporate, they leave behind dissolved material that is present in the water, generating ambient particulate matter (PM). Thus, misting systems are a point source of PM. Currently there is no information on their impact on air quality in close proximity to these systems, or on the chemical composition of the particulate matter generated by the evaporating mist.
In this project, PM concentrations are found to increase on average by a factor of 8 from ambient levels in the vicinity of a residential misting system in controlled experiments. PM concentrations in public places that use misting systems are also investigated. The PM10 concentrations in public places ranged from 0.102 ± 0.010 mg m-3 to 1.47 ± 0.15 mg m-3, and PM2.5 ranged from 0.095 ± 0.010 mg m-3 to 0.99 ± 0.10 mg m-3. Air quality index (AQI) values based on these concentrations indicate that these levels of PM range from unhealthy to hazardous in most cases. PM concentrations tend to decrease after remaining relatively constant with increasing distance from misting systems. Chemical data reveal that chloride and magnesium ions may be used as tracers of aerosolized water from misting systems. The average chloride concentration was 71 µg m-3 in misting samples and below the detection limit for Cl- (< 8.2 µg m-3) in ambient samples. The average magnesium concentration was 11.7 µg m-3 in misting samples and 0.23 µg m-3 in ambient samples.
-see the additional "abstract.pdf" document for formatting
In arid environments like Phoenix, many professional and residential outdoor spaces are cooled by the use of misting systems. These systems spray a fine mist of water droplets that cool down the surrounding air through the endothermic evaporation process. When the water droplets evaporate, they leave behind dissolved material that is present in the water, generating ambient particulate matter (PM). Thus, misting systems are a point source of PM. Currently there is no information on their impact on air quality in close proximity to these systems, or on the chemical composition of the particulate matter generated by the evaporating mist.
In this project, PM concentrations are found to increase on average by a factor of 8 from ambient levels in the vicinity of a residential misting system in controlled experiments. PM concentrations in public places that use misting systems are also investigated. The PM10 concentrations in public places ranged from 0.102 ± 0.010 mg m-3 to 1.47 ± 0.15 mg m-3, and PM2.5 ranged from 0.095 ± 0.010 mg m-3 to 0.99 ± 0.10 mg m-3. Air quality index (AQI) values based on these concentrations indicate that these levels of PM range from unhealthy to hazardous in most cases. PM concentrations tend to decrease after remaining relatively constant with increasing distance from misting systems. Chemical data reveal that chloride and magnesium ions may be used as tracers of aerosolized water from misting systems. The average chloride concentration was 71 µg m-3 in misting samples and below the detection limit for Cl- (< 8.2 µg m-3) in ambient samples. The average magnesium concentration was 11.7 µg m-3 in misting samples and 0.23 µg m-3 in ambient samples.
Date Created
2020-05
Contributors
- Knight, William Louis (Co-author)
- Knight, William (Co-author)
- Herckes, Pierre (Thesis director)
- Fraser, Matthew (Committee member)
- Hamilton, Kerry (Committee member)
- School of Sustainability (Contributor)
- School of Molecular Sciences (Contributor)
- Barrett, The Honors College (Contributor)
Topical Subject
Extent
21 pages
Language
eng
Copyright Statement
In Copyright
Primary Member of
Series
Academic Year 2019-2020
Handle
https://hdl.handle.net/2286/R.I.56676
Level of coding
minimal
Cataloging Standards
System Created
- 2020-04-29 12:00:09
System Modified
- 2021-08-11 04:09:57
- 3 years 3 months ago
Additional Formats