Background: Magnetic Resonance Spectroscopic Imaging (MRSI) has wide applicability for non-invasive biochemical assessment in clinical and pre-clinical applications but suffers from long scan times. Compressed sensing (CS) has been successfully applied to clinical H-1 MRSI, however a detailed evaluation of CS for conventional chemical shift imaging is lacking. Here we evaluate the performance of CS accelerated MRSI, and specifically apply it to accelerate Na-23-MRSI on mouse hearts in vivo at 9.4 T.
Methods: Synthetic phantom data representing a simplified section across a mouse thorax were used to evaluate the fidelity of the CS reconstruction for varying levels of under-sampling, resolution and signal-to-noise ratios (SNR). The amplitude of signals arising from within a compartment, and signal contamination arising from outside the compartment relative to noise-free Fourier-transformed (FT) data were determined. Simulation results were subsequently verified experimentally in phantoms and in three mouse hearts in vivo.
Results: CS reconstructed MRSI data are scaled linearly relative to absolute signal intensities from the fully-sampled FT reconstructed case (R-2 > 0.8, p-value < 0.001). Higher acceleration factors resulted in a denoising of the reconstructed spectra, but also in an increased blurring of compartment boundaries, particularly at lower spatial resolutions. Increasing resolution and SNR decreased cross-compartment contamination and yielded signal amplitudes closer to the FT data. Proof-of-concept high-resolution, 3-fold accelerated Na-23-amplitude maps of murine myocardium could be obtained within similar to 23 mins.
Conclusions: Relative signal amplitudes (i.e. metabolite ratios) and absolute quantification of metabolite concentrations can be accurately determined with up to 5-fold under-sampled, CS-reconstructed MRSI. Although this work focused on murine cardiac Na-23-MRSI, the results are equally applicable to other nuclei and tissues (e.g. H-1 MRSI in brain). Significant reduction in MRSI scan time will reduce the burden on the subject, increase scanner throughput, and may open new avenues for (pre-) clinical metabolic studies.
- Maguire, Mahon L. (Author)
- Geethanath, Sairam (Author)
- Lygate, Craig A. (Author)
- Kodibagkar, Vikram (Author)
- Schneider, Juergen E. (Author)
- Ira A. Fulton Schools of Engineering (Contributor)
Maguire, Mahon L., Geethanath, Sairam, Lygate, Craig A., Kodibagkar, Vikram D., & Schneider, Juergen E. (2015). Compressed sensing to accelerate magnetic resonance spectroscopic imaging: evaluation and application to Na-23-imaging of mouse hearts. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 17. http://dx.doi.org/10.1186/s12968-015-0149-6
- 2015-10-14 11:01:24
- 2021-10-26 04:08:19
- 3 years ago