Background: The Nike + Fuelband is a commercially available, wrist-worn accelerometer used to track physical activity energy expenditure (PAEE) during exercise. However, validation studies assessing the accuracy of this device for estimating PAEE are lacking. Therefore, this study examined the validity and reliability of the Nike + Fuelband for estimating PAEE during physical activity in young adults. Secondarily, we compared PAEE estimation of the Nike + Fuelband with the previously validated SenseWear Armband (SWA).
Methods: Twenty-four participants (n = 24) completed two, 60-min semi-structured routines consisting of sedentary/light-intensity, moderate-intensity, and vigorous-intensity physical activity. Participants wore a Nike + Fuelband and SWA, while oxygen uptake was measured continuously with an Oxycon Mobile (OM) metabolic measurement system (criterion).
Results: The Nike + Fuelband (ICC = 0.77) and SWA (ICC = 0.61) both demonstrated moderate to good validity. PAEE estimates provided by the Nike + Fuelband (246 ± 67 kcal) and SWA (238 ± 57 kcal) were not statistically different than OM (243 ± 67 kcal). Both devices also displayed similar mean absolute percent errors for PAEE estimates (Nike + Fuelband = 16 ± 13 %; SWA = 18 ± 18 %). Test-retest reliability for PAEE indicated good stability for Nike + Fuelband (ICC = 0.96) and SWA (ICC = 0.90).
Conclusion: The Nike + Fuelband provided valid and reliable estimates of PAEE, that are similar to the previously validated SWA, during a routine that included approximately equal amounts of sedentary/light-, moderate- and vigorous-intensity physical activity.
Details
- Validity and Reliability of Nike + Fuelband for Estimating Physical Activity Energy Expenditure
- Tucker, Wesley (Author)
- Bhammar, Dharini M. (Author)
- Sawyer, Brandon J. (Author)
- Buman, Matthew (Author)
- Gaesser, Glenn (Author)
- College of Health Solutions (Contributor)
- Digital object identifier: 10.1186/s13102-015-0008-7
- Identifier TypeInternational standard serial numberIdentifier Value2052-1847
- The electronic version of this article is the complete one and can be found online at: http://bmcsportsscimedrehabil.biomedcentral.com/articles/10.1186/s13102-015-0008-7
Citation and reuse
Cite this item
This is a suggested citation. Consult the appropriate style guide for specific citation guidelines.
Tucker, W. J., Bhammar, D. M., Sawyer, B. J., Buman, M. P., & Gaesser, G. A. (2015). Validity and reliability of Nike Fuelband for estimating physical activity energy expenditure. BMC Sports Science, Medicine and Rehabilitation, 7(1). doi:10.1186/s13102-015-0008-7