Description

This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles

This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of ∼40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from ∼35 to ∼300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 1012 photons per µm2 per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. The results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.

Reuse Permissions
  • Downloads
    PDF (2.4 MB)

    Details

    Title
    • Experimental Strategies for Imaging Bioparticles With Femtosecond Hard X-Ray Pulses
    Date Created
    2017-04-07
    Resource Type
  • Text
  • Collections this item is in
    Identifier
    • Digital object identifier: 10.1107/S2052252517003591
    • Identifier Type
      International standard serial number
      Identifier Value
      2052-2525
    Note
    • View the article as published at http://journals.iucr.org/m/issues/2017/03/00/it5009/index.html

    Citation and reuse

    Cite this item

    This is a suggested citation. Consult the appropriate style guide for specific citation guidelines.

    Daurer, B. J., Okamoto, K., Bielecki, J., Maia, F. R., Mühlig, K., Seibert, M. M., . . . Larsson, D. S. (2017). Experimental strategies for imaging bioparticles with femtosecond hard X-ray pulses. IUCrJ, 4(3), 251-262. doi:10.1107/s2052252517003591

    Machine-readable links